Weight data not displayed in software

Solution: configure software client correctly (according to the manual) Solution: replace indicator including housing and all internal PCBs (order replacement ones)

By |2020-11-09T11:30:04+02:00November 9th, 2020|Comments Off on Weight data not displayed in software

Wrong weight is shown in indicator and in software, alternative unstable weight

Solution: make sure there are no cables are snagged in between chassis components of the Parcelcube. Make sure you have no items touching the Parcelcube or the Parcelcube itself is pressing against a wall or other object Solution: one or more loadcells are broken (order replacement ones) Solution: indicator is in need of calibration (calibrate [...]

By |2020-11-09T11:30:11+02:00November 9th, 2020|Comments Off on Wrong weight is shown in indicator and in software, alternative unstable weight

Scale dimension data is incorrect

Solution: send to Parcelcube support pictures what you try to measure, the items you try to measure is hard to detect for Parcelcube. They might be round, plastic bags or non-boxed items like a shampoo bottle. Advice is to use the metal brackets that are included, still there are limitations.

By |2020-11-09T11:30:37+02:00November 9th, 2020|Comments Off on Scale dimension data is incorrect

Empty scale shows a random dimension on any of the axis, most commonly x or y

Solution: Items placed too close to the Parcelcube need to be moved Solution: Parcelcube cannot be placed next to a brick wall or alike. Solution: side walls are bent out of shape or extremely dirty / filled with tape residue or alike. Clean it up. Solution: older Parcelcube without their red sensor glasses, should be [...]

By |2020-11-09T11:30:48+02:00November 9th, 2020|Comments Off on Empty scale shows a random dimension on any of the axis, most commonly x or y